GE552-1

Thermal energy meters for use in boiler room

VOLUMETRIC VERSION
Heat energy meters with double register, for use in a boiler room, for measuring heating and/or air-conditioning consumption. Complete with:
- Electronic processing unit
- Flow rate measurement section
- Available in threaded or flanged versions
- Impulsive inputs for sanitary impulse water meters
- Two housings for water temperature probes
- Two housings for water temperature probes
(delivery and return)
- Two water temperature probes (delivery and return)
- Casing protection degree IP65
- Powered with lithium battery (> 6-year lifespan)
- Pre-arranged for data communication in accordance
with M-BUS (EN 1434)
- Fluid temperature range 1÷90 °C
(meters with threaded connections)
- Fluid temperature range 1÷120 °C
(meters with flanged connections)
- Ambient temperature range 5÷55 °C
- EC marks
- Certified in accordance with MID Directive 2004/22/EC

GE552Y231 - 1 1/4" Threaded connection
Nominal flow rate: 6 m3/h
Supply: battery
Centre distance: 260 mm
Data centralization type: M-Bus

GE552Y233 - 1 1/2" Threaded connection
Nominal flow rate: 6 m3/h
Supply: battery
Centre distance: 260 mm
Data centralization type: M-Bus

GE552Y235 - 2" Threaded connection
Nominal flow rate: 10 m3/h
Supply: battery
Centre distance: 300 mm
Data centralization type: M-Bus

GE552Y243 - DN50 Flanged connection
Nominal flow rate: 15 m3/h
Supply: battery
Centre distance: 200 mm
Data centralization type: M-Bus

GE552Y245 - DN65 Flanged connection
Nominal flow rate: 25 m3/h
Supply: battery
Centre distance: 200 mm
Data centralization type: M-Bus

GE552Y247 - DN80 Flanged connection
Nominal flow rate: 40 m3/h
Supply: battery
Centre distance: 225 mm
Data centralization type: M-Bus

GE552Y249 - DN100 Flanged connection
Nominal flow rate: 60 m3/h
Supply: battery
Centre distance: 250 mm
Data centralization type: M-Bus

GE552Y251 - DN125 Flanged connection
Nominal flow rate: 100 m3/h
Supply: battery
Centre distance: 250 mm
Data centralization type: M-Bus

GE552Y253 - DN150 Flanged connection
Nominal flow rate: 150 m3/h
Supply: battery
Centre distance: 300 mm
Data centralization type: M-Bus

GE552Y255 - DN200 Flanged connection
Nominal flow rate: 250 m3/h
Supply: battery
Centre distance: 350 mm
Data centralization type: M-Bus
______________________________________________________________

ULTRASOUNDS VERSION
Heat energy meters with double register, for use in a boiler room, for measuring heating and/or air-conditioning consumption. Complete with:
- Electronic processing unit
- Flow rate measurement section
- Available in threaded or flanged versions
- Impulsive inputs for sanitary impulse water meters
- Two housings for water temperature probes
(delivery and return)
- Two water temperature probes (delivery and return)
- Casing protection degree IP64
- Powered with lithium battery (12-year lifespan)
- Pre-arranged for data communication in accordance
with M-BUS (EN 1434)
- Fluid temperature range 1÷150 °C
- Ambient temperature range 5÷55 °C
- EC marks
- Certified in accordance with MID Directive 2004/22/EC

GE552Y131 - 1 1/4" Threaded connection
Nominal flow rate: 3,5 m3/h
Supply: battery
Centre distance: 260 mm
Data centralization type: M-Bus

GE552Y133 - 1 1/4" Threaded connection
Nominal flow rate: 6 m3/h
Supply: battery
Centre distance: 260 mm
Data centralization type: M-Bus

GE552Y135 - 2" Threaded connection
Nominal flow rate: 10 m3/h
Supply: battery
Centre distance: 300 mm
Data centralization type: M-Bus

GE552Y139 - DN25 Flanged connection
Nominal flow rate: 6 m3/h
Supply: battery
Centre distance: 260 mm
Data centralization type: M-Bus

GE552Y141 - DN40 Flanged connection
Nominal flow rate: 10 m3/h
Supply: battery
Centre distance: 300 mm
Data centralization type: M-Bus

GE552Y143 - DN50 Flanged connection
Nominal flow rate: 15 m3/h
Supply: battery
Centre distance: 270 mm
Data centralization type: M-Bus

GE552Y145 - DN65 Flanged connection
Nominal flow rate: 25 m3/h
Supply: battery
Centre distance: 300 mm
Data centralization type: M-Bus

GE552Y147 - DN80 Flanged connection
Nominal flow rate: 40 m3/h
Supply: battery
Centre distance: 300 mm
Data centralization type: M-Bus

GE552Y149 - DN100 Flanged connection
Nominal flow rate: 60 m3/h
Supply: battery
Centre distance: 360 mm
Data centralization type: M-Bus

Volumetric version
Šifra Dimenzija Pack Single Pack Multiple
GE552Y231 1 1/4" 6 m3/h threaded 1 -
GE552Y233 1 1/2" 6 m3/h threaded 1 -
GE552Y235 2" 10 m3/h threaded 1 -
GE552Y243 DN50 15 m3/h flanged 1 -
GE552Y245 DN65 25 m3/h flanged 1 -
GE552Y247 DN80 40 m3/h flanged 1 -
GE552Y249 DN100 60 m3/h flanged 1 -
GE552Y251 DN125 100 m3/h flanged 1 -
GE552Y253 DN150 150 m3/h flanged 1 -
GE552Y255 DN150 250 m3/h flanged 1 -
Ultrasounds version
Šifra Dimenzija Pack Single Pack Multiple
GE552Y131 1 1/4" 3,5 m3/h threaded 1 -
GE552Y133 1 1/4" 6 m3/h threaded 1 -
GE552Y135 2" 10 m3/h threaded 1 -
GE552Y139 DN25 6 m3/h flanged 1 -
GE552Y141 DN40 10 m3/h flanged 1 -
GE552Y143 DN50 15 m3/h flanged 1 -
GE552Y145 DN65 25 m3/h flanged 1 -
GE552Y147 DN80 40 m3/h flanged 1 -
GE552Y149 DN100 60 m3/h flanged 1 -
Drugi proizvodi "Direct and indirect thermal energy metering"